Generator Electrostatic Discharge Generator ESD300kV

This electrostatic discharge generator is specially designed to simulate whether an aircraft, a rocket, a missile or weapon systems can operate safely, reliably, or be damaged after being subjected to a buildup of static electricity when flying at high speed through the sky.
It has a discharge voltage of up to 300kV, in compliance with standards such as MIL-STD-464D, MIL-STD-331D, GJB1389A, GJB573A, etc.
SXESD300 is used for Helicopter-borne ESD test and High Voltage Corona.
The inductance shall be determined at a nominal 1kHz frequency.

Additional Product Information

Features & Benefits
  1. HV non-inductance impulse capacitors are adopted.
  2. Transportable with wheels at the base frames.
  3. User friendlytouch panel for remote control.
  4. Automatic measurement system with optical fibre and precise current monitor.
  5. Considerate safety measures
  • Automatic grounding system- after each test, the system will automatically be grounded to discharge the energy.
  • Manual earthing rod.
  • Door safety interlock.
  • Audible and visual alarm.
  • Emergency stop button.
Applications

SXESD300 is used for Helicopter-borne ESD test and High Voltage Corona.

The inductance shall be determined at a nominal 1kHz frequency.

This electrostatic discharge generator is specially designed to simulate whether an aircraft, a rocket, a missile or weapon systems can operate safely, reliably, or be damaged after being subjected to a buildup of static electricity when flying at high speed through the sky.

Technical Parameters
Impulse capacitor 1000pF
 Resistance of test circuit during test <1 Ohm
Voltage calibration 100Ω Calibration Test Load;

Ratio:1000:1;

 

Voltage of capacitor 25~360KV
Power supply requirement AC220V±10%,5kVA (current>30A), use L1-N
Considerate Safety Measures

 

1)      Automatic grounding system- after each test, the system will automatically be grounded to discharge the energy.

2)      Manual earthing rod;

3)      Door safety interlock;

4)      Alarming system with red light flickering and alarming bell ringing during charging;

5)      Emergency stop button- in case of emergency, press this button to stop the system, HV terminal will be grounded automatically.

Scope of Supply

Part Name Technical Data Quantity
1 HV DC generator

 

Output voltage:max.+360kV/-360kV;

Output current:10mA continuous;

Power:4kVA;

Ripple factor:≤3%;

Over current protection: max. 10A transient;

Protection: over voltage protection, over current protection, voltage loss protection, discharge protection.

2
2 Protective resistor Resistance:500k Ω;

Power:500W;

Function: protect the DC generator in case of over current and test specimen breakdown

1
3 Non-inductive capacitor Impulse capacitor;

Rated voltage:360kV;

Rated capacitance:1nF;

Structure: epoxy tube with corona ring at the top

1
4 Discharge resistor Resistance:100Ω;

Non inductive

1
5 Electrostatic discharge holder Max. 4m high;

Discharge distance:3m;

Discharge sphere: copper;

Adjustable range of discharge ball direction:±60°

1
6 Sedimentary charge test holder Max. 4m high, adjustable height;

Discharge distance:3m;

Withstand 300kV;

With sedimentary charge discharge;

Discharge sphere: copper;

Adjustable range of discharge ball direction:±60°

1
7 Manual earthing rod 2m long, max. discharge voltage is 360kV, discharge resistor 100MΩ/0Ω 1
8 MCS2000 10’ touch panel, control software, PLC controlled 1
9 iMas3000 Measurement software to analyze the output wave, test report 1
10 Oscilloscope MDO32-350MHz, 2 channels 1
11 Voltage calibration 100Ω, Calibration Test Load, ratio:1000:1;

 

1
12 Current acquisition unit 0.01V/A, Max.10kA;

With measurement transfer unit, measure and output current wave;

With optical fiber transmission system, analog quantity optical acquisition module

1
13 HV DC Volt Meter Leakage current:0.1mA;

Used with 400kV resistive voltage divider

for the calibration of charging voltage;

 

14 HV DC resistive voltage divider

(optional)

 

Rated voltage:400kV;

Structure: epoxy tube with corona ring at the top;

Resistance:5GΩ;

Measuring accuracy:<1%

1

 

 

 

 

 

 

 

Standards
  • MiL-STD-464D Electromagnetic environmental effects requirements for systems
  • MIL-STD-331D Department of Defense Test Method Standard for Fuzes, Ignition Safety Devices and Other Related Components, Environmental and Performances Tests
  • GJB1389A Electromagnetic compatibility requirements for systems
  • GJB573A Fuze environmental and performance test methods
© 2016-2026 Sanmen Shixuan Electric Co.,Ltd. All Rights Reserved. Site Map | Terms of Use | Terms and Conditions